Description
Performance
Test conditions (unless otherwise stated): normal temp., 15V±1V
Parameter | Unit | Parameter |
Pressure Range | MPa | 0~0.1, 0~2, 0~5 |
Pressure | – | Absolute pressure, sealed gauge pressure |
Overload Pressure | – | 200% |
Pressure precision Grade | %.F.S | 0.5(-40°C ~+85°C);
1.0(-55°C ~+150°C) |
Non-linear | %.F.S | <0.15 |
Hysteresis | %.F.S | <0.075 |
Repeatability | %.F.S | <0.075 |
Temp. Range | °C | -55~+150 |
Temp. precision Grade | %.F.S | 0.5(-40°C ~+125°C), 1.0(-55°C ~+150°C) |
Supply voltage | V | 8~36 (Voltage typ.+15) |
V | 0.5~4.5 | |
Pressure, Temp. signal Output | mA | Three-wire system: 4~20 |
Weight | g | <200 |
Operating Temp. | °C | -55~+150 |
Storage Temp. | °C | -55~+150 |
Application
- Aviation, aerospace hydraulic system, oxygen supply system
- Deicing system, power system
- Industrial process control
Dimensions and Wiring Definition
Dimensions |
Output Wiring Definition |
||
![]() |
Connector: J599 I Series | ||
Contact | Mark | Description | |
1 | PVCC1+ | Pressure 1 Power+ | |
2 | PGND1 | Pressure 1 Power GND | |
3 | POUT1 | Pressure 1 Signal Output | |
4 | PVCC2+ | Pressure 2 Power+ | |
5 | PGND2 | Pressure 2 Power GND | |
6 | POUT2 | Pressure 2 Signal Output | |
7 | TVCC1+ | Temp. 1 Power+ | |
8 | TGND1 | Temp. 1 Power GND | |
9 | TOUT1 | Temp. 1 Signal Output | |
10 | TVCC2+ | Temp. 2 Power+ | |
11 | TGND2 | Temp. 2 Power GND | |
12 | TOUT2 | Temp. 2 Signal Output |