Description
Performance
Test conditions (unless otherwise stated): normal temp., 15V±1V
Parameter | Unit | Parameter |
Range | °C | -55°C~+150°C |
Precision Grade | %.F.S | 1.0(-40°C~+85°C),
1.5(-55~150°C) |
Supply voltage | V | 8~36 (Voltage typ.+15) |
V | 0.5 ~ 4.5 | |
Signal Output | mA | Three-wire system: 4~20 |
Weight | g | <50 |
Operating Temp. | °C | -55~+150 |
Storage Temp. | °C | -55~+150 |
Application
- Aviation and aerospace hydraulic systems
- Oxygen supply system
- In-cabin pressure detection
Dimensions and Wiring Definition
Dimensions |
Output Wiring Definition |
||
![]() |
Contact | Mark | Description |
1Red | VCC+ | Power+ | |
2Black | GND | Power GND | |
3Green | OUT | Signal Output |