Features
- Single phase output
 - Over current protection, short circuit protection
 - Overvoltage protection, under-voltage protection
 - Over temperature protection
 - Voltage, current, temperature, frequency detection
 - Small size and light weight
 - High output power
 
Main Technical Characteristics
| Input | Input control power | DC20V~DC36V (With reverse connection protection) | 
| Static operating current | ≤100mA | |
| Output | Input power | AC80V~AC280V | 
| Output power | Output current (10A~50A) can be set | |
| Output leakage current | <10mA | |
| Voltage drop | <2Va.c. | |
| Switch | Zero crossing | |
| Control | Bus control or emergency control | |
| Cooling system | Heat sink | |
| Rated short-circuit breaking capacity | 500A | |
| Other parameters | Sampling error | Voltage: ±1%; Current: ±5%; Temperature: ±1°C | 
| Communication Interface | CAN2.0B, extended frame, communication rate 250kbps | |
| Protective function | Over current, over voltage, under voltage, short circuit, over temperature protection, parameters can be set | |
| Insulation resistance | 500Vd.c., >100MΩ | 
Environmental parameters
| Item | Min | Max | Unit | 
| Operating temperature | -45 | 85 | °C | 
| Storage temperature | -55 | 85 | °C | 
| Shock | 100, 11 | (m/s2), ms | |
| Vibration (high frequency) | 10, 10~2000 | (m/s2)2, Hz | |
| Application instruction | Load characteristics | 
![]()  | 
![]()  | 
| Installation dimension (unit: mm) | |
 
Note: The tolerance of dimension is according to GB/T1804-m if not mentioned.  | 
|
Order mark
| TZ220AC | – | 50 | 1 | Z1 | 
| Main code | Output current | Protection curve | Customization sign | 
Note:
- The maximum rated output current is 50A.
 - The overcurrent protection curve can be selected from 1 to 8.
 - If there is need to customize the bus communication protocol, you can sign a special technical agreement in which the order mark is determined.
 